Omega Healthcare Medical Equipments SupplierOmega Healthcare Medical Equipments Supplier

Air and Surface Disinfector  UV-C Sterilon Flow 72W

Click on image to view full picture

Product Code: LEN-240416 *
 £395.16 
 (£329.30 Ex. VAT) 
Add to Cart
OR

Free UK Shipping

Quick Overview

The UV-C STERILON FLOW is not only suitable for air disinfection but also for direct surface disinfection. 
 
UV-C radiation is used in this case as well, as the surface is directly irradiated by ultraviolet light. 
 
For this purpose, the cover of the device is removed in order to use the internal UV-C lamps as emitters.
 
You can remove one cover for surface disinfection in one or two directions. 
 
At a distance of one metre, the irradiation area is 7m² .
 
Direct surface disinfection function
After opening the light source’s cover, the lamp should be directed at the surface for a specified time to effectively disinfect it. 
However, it should be remembered that UV-C light is harmful to the skin and eyes. 
When using the lamp in this form, no one should be in the range of the light beam. 
A careful reading of the user manual is required before use.
 
Features
Range of effective disinfection - room capacity 25m2/75m3
UV-C Sterilon Flow 72W with safety screw & hour counter
Free-standing with cable
Air and surface disinfector in one
Removes viruses, bacteria, fungi from the ambient air and surfaces
Air disinfection via air flow
Direct surface disinfection in two directions (WARNUNG! Please read the safety instructions!)
Uses ultraviolet UV-C light (wave length: 253.7nm)
With dust filter
Space for EPA filter (available as a separate accessory)
Light source with approx. 9000h service life
Frosted white housing, silver galvanised front
With bracket to remove the cover and to carry the device
Level of impermeability: IP20
Easy operation with ON/OFF switch
3m long power cable
Available in 2 versions: 72W or 144W
Type of light: UV-C ultraviolet
Colour: white matt body, galvanised silver front
Air-flow: 160 m3/h
Dust filter
Compartment for a HEPA filter
Light source lifespan: 9000h
The maximum volume (cubature) of the disinfected room during air-flow disinfection is about 25 m2 (~75m3)
Noise level: 42 dB
The irradiation area for direct disinfection from a distance of 1m is 7 m2
UV-C Wavelength: 253.7 nm
Supply voltage: 220-240V
Total power consumption: 82W
Class of protection against electric shock: I
Ingress protection class: IP20
Power cord: 3m
ON/OFF switch
Compartment for a HEPA filter
 
Application
Medical practices
Hospitals
Healthcare facilities of all kinds
Business spaces
Educational institutions and care facilities
Public facilities
Offices
Hair and beauty salons
 
 
Please follow the safety instructions of the manufacturer concerning UV-C radiation. 
 
The instructions can be found here.
 



View Product Manuals/Spec Sheet



Safety_UV-C_STERILON_FLOW (1).pdf  Safety_UV-C_STERILON_FLOW (1).pdf