Perfect Pelvic Floor Trainer for Men

Click on image to view full picture

  • Perfect Pelvic Floor Trainer for Men
  • Perfect Pelvic Floor Trainer for Men
Product Code: TENSC-K-PPFE-MEN
Brand: TensCare
 £79.00 
 (£65.83 Ex. VAT) 
Add to Cart
OR

Quick Overview

Pelvic floor trainer with electrodes and anal probe 
 
Fecal incontinence can affect men as well as women, particularly for those with postprostatectomy incontinence. To address the issue many, choose to ignore, Tenscare have created a version of the Perfect PFE unit specifically for men.
 
Perfect PFE MEN sends a gentle stimulation (similar to your natural nerve impulses) direct to your pelvic floor muscles through an anal probe with stainless steel electrodes or with optional electrode pads. These signals make your pelvic floor muscles contract, toning them for you to help you regain control over them and fight bladder weakness.
 
The Perfect PFE MEN also has a programme designed to provide pelvic pain relief in addition to the programmes fighting bladder weakness. The conditions it addresses are chronic prostatitis and chronic pelvic pain syndrome.
 
Additionally, Perfect PFE MEN Pelvic Floor Exerciser helps maintaining healthy bowel movement, improving pelvic strength, and amplifying rectal sensation for enhanced pleasure. It can also help you to perform the exercises recommended for recovery from Erectile Dysfunction.
 
Features
Single channel unit to treat symptoms of urinary and faecal incontinence via an anal probe via adjustable depth.
Gentle stimulation with fine tune adjustment settings for different levels of intensity.
5 Pre-set Programmes.
EMS programmes including STRES, URGE, MIXED and TONE aftercare; and additional TENS programme providing relief from prostatitis pain and pelvic pain.
Treatment Timer.
Unit defaults to 20 minutes’ treatment to ensure the pelvic floor muscles are not over-worked. The user can manually reset this.
Automatically resets the strength to zero and flashes ‘LEADS’ if the connection comes loose.
Automatic keypad lock prevents any accidental changes in settings.
Large LCD screen clearly shows the operation of the unit and the programme and intensity being used.
 
What's Included
1 x Perfect PFE for men continence stimulator unit
1 x Go Gel 50 ml
1 x Lead wire (L-CPT)
1 x Anal probe (X-PR13)
4 x 50x50 mm electrode pads (E-CM5050)
2 x AA 1.5V alkaline batteries
1 x Detachable belt clip
1 x Storage pouch
1 x Manual instruction
 
Please Note 
Do NOT use with optional electrode pads if you have a pacemaker (or if you have a heart rhythm problem) or with any electronic medical devices.
Using this unit with electronic medical devices may cause erroneous operation of the device.
Stimulation in the direct vicinity of an implanted device may affect some models.
Stimulation on the front of the neck can affect your heart rate. Very strong stimulation across the chest may cause an extra heartbeat.
Do NOT use in the first 6 weeks following a surgery in the area being treated. Stimulation may disrupt the healing process.
Do NOT use if you have symptoms of active urinary tract infection or localized lesions. Introducing the probe may irritate sensitive tissue.
Do NOT use if you have poor sensation in the pelvic region. You may not be able to control the intensity of stimulation safely.  
WARNINGS:
Do NOT use if you are unable to properly insert the probe. If you have a severe prolapse, or if any discomfort occurs when inserting the probe, consult your healthcare professional before use.
Do NOT use when driving, operating machinery, or similar actions needing muscular control. Loose electrode pads, damaged leads, or sudden changes in contact may cause brief involuntary muscle movements.
Do NOT use to mask or relieve undiagnosed pain. This may delay diagnosis of a progressive condition.
Do NOT use if you have, in the area being treated: active or suspected cancer or undiagnosed pain with a history of cancer. Stimulation directly through a confirmed or suspected malignancy should be avoided as it may stimulate growth and promote spread of cancer cells.
 
Caution 
Caution should be used if you have a bleeding disorder as stimulation may increase blood flow to the stimulated region.
Caution should be used if you have suspected or diagnosed epilepsy as electrical stimulation may affect seizure threshold.
Caution should be observed when using the device at the same time as being connected to monitoring equipment with body worn electrode pads. It may interfere with the signals being monitored.
Simultaneous connection to high frequency surgical equipment may result in burns and damage to the stimulator.
Strong electromagnetic fields (electrosurgery/ microwave cookers/ mobile phones) may affect the correct operation of this unit. If it appears to behave unusually, move it away from these devices.
Caution should be observed when using the perfect PFE at high strength settings. Prolonged use at high settings may cause muscle injury or tissue inflammation.
No serious or long-term adverse effects have been reported. Mild adverse reactions are very rarely reported, but these have included muscular pain and cramps, irritation and bleeding, mild or short-term urge or faecal incontinence, and tingling sensation in legs. If you experience any of these, stop use. When symptoms have gone, try resuming at a lower intensity setting.
 
Probe Caution
The perfect PFE anal probe is intended for single patient use only.
Do not share your perfect PFE probe with anyone else. Improper treatment or cross-infection may occur.
It is important that the anal probe is cleaned after each use. Ineffective cleaning may lead to irritation or infection.
Never insert or remove anal probe unless the control unit is powered OFF as insertion or removal when stimulation is active may cause discomfort or tissue irritation.
If tissue irritation occurs, discontinue treatment immediately. Ask your healthcare professional for advice before continuing further treatment to prevent injury.
Do not use a silicone-based lubricant on the metal plates of the probe as it may decrease the effectiveness of perfect PFE’s muscle stimulation.
The stainless steel in the probe’s metal plates contain some Nickel. This could cause a reaction if you have a Nickel allergy. Alternative gold probe specially made without Nickel is available on request 
Do not use this device with anal probe other than those recommended by the manufacturer.
 
Electrodes Caution
Electrodes with smaller surface area may cause tissue irritation.
Do not ignore any allergic reaction to the electrode pads: if a skin irritation develops, stop using TENS, as this type of electrodes may not be suitable for you. Alternative electrode pads specially made for sensitive skin are available.
Do not use this device with leads or electrode pads other than those recommended by the manufacturer. Performance may vary from specification.
Electrodes with smaller surface area may cause tissue irritation.
 
 



View Product Manuals/Spec Sheet