Easy-to-use, flexible pelvic floor exerciser with a wide range of pre-set and manual programs
The SurePro pelvic floor trainer provide a discreet, affordable and long-term solution for incontinence sufferers.
It provides relief from 3 forms of incontinence:
Stress Incontinence: Involuntary leakage of urine when a person coughs, sneezes, strains or makes sudden movements.
Urge Incontinence: Overactive bladder. A person may experience a strong and sudden urge to go to the toilet but are not always able to hold on or have to go so frequently that it becomes inconvenient.
Mixed Incontinence: A combination of both stress and urge incontinence.
The Sure PRO has 12 pre-set and 3 manual programmes. In addition to the standard settings, it has special programmes for transcutaneous tibial nerve stimulation (TTNS) for urge incontinence. The manual programmes can be adjusted by healthcare professionals to the specific needs of the patient.
Features
It is easy to use with pre-set programmes to suit your needs.
Transcutaneous Tibial Nerve Stimulation (TTNS);
Automatic keypad lock and manual program lock to ensure your program doesn't change accidentally.
Locking lead connection & built-in cable tidy ensure leads remain in place and out of the way.
Safety feature to prevent any sudden increases in stimulation.
Modern, colour screen enabling quick access and control.
Optional Programs – 12 pre-set and 3 manual programs for optimal choice.
Work/Rest Ratio Warning to ensure you do not overwork your muscles.
Gentle, comfortable stimulation with fine-tune adjustment settings for levels of intensity.
Rechargeable li-ion battery.
Sufficient memory for a 90-day, daily treatment program.
Dual Channel – 2 independent channels can be used with vaginal or anal electrodes, or 4 self-adhesive electrode pads.
2 Years Warranty
( This warranty refers to the unit only. It does not cover, electrode pads, battery, or the lead wires.)
Box Content: Sure Pro, continence stimulator unit, 2 Lead wires, Liberty vaginal probe, 4 x 50x50mm electrode pads, Li-ion battery, charging cradle, mains adaptor (EU/UK) detachable belt clip, storage pouch and instructions for use
Please Note
Do NOT use if you are or may be pregnant.
Do NOT use with optional electrode pads if you have a pacemaker (or if you have a heart rhythm problem) or with any electronic medical devices. Using this unit with electronic medical devices may cause erroneous operation of the device.
Stimulation on the front of the neck can affect your heart rate.
Very strong stimulation across the chest may cause an extra heartbeat.
Do NOT use in the first 6 weeks following a pelvic surgery or vaginal childbirth. Stimulation may disrupt the healing process.
Do NOT use if you have symptoms of active urinary tract infection, vaginal infections, or localized lesions. Introducing the probe may irritate sensitive tissue.
Do NOT use if you have poor sensation in the pelvic region. You may not be able to control the intensity of stimulation safely.
Do NOT use if you are unable to properly insert the vaginal or anal probe.
If you have a severe prolapse, or if any discomfort occurs when inserting the probe, consult your healthcare professional before use.
Do NOT use when driving, operating machinery, or similar actions needing muscular control. Loose electrode pads, damaged leads, or sudden changes in contact may cause brief involuntary muscle movements.
Do NOT use to mask or relieve undiagnosed pain. This may delay diagnosis of a progressive condition.
Do NOT use if you have, in the area being treated: active or suspected cancer or undiagnosed pain with a history of cancer. Stimulation directly through a confirmed or suspected malignancy should be avoided as it may stimulate growth and promote spread of cancer cells.
Caution
Caution should be used if you have a bleeding disorder as stimulation may increase blood flow to the stimulated region.
Caution should be used if you have suspected or diagnosed epilepsy as electrical stimulation may affect seizure threshold.
Caution should be observed when using the device at the same time as being connected to monitoring equipment with body worn electrode pads. It may interfere with the signals being monitored.
Simultaneous connection to high frequency surgical equipment may result in burns and damage to the stimulator.
Strong electromagnetic fields (electrosurgery/ microwave cookers/ mobile phones) may affect the correct operation of this unit. If it appears to behave unusually, move it away from these devices.
Do not permit use by persons unable to understand the instructions or persons with cognitive disabilities, i.e., Alzheimer’s disease or dementia.
Caution should be observed when using the Sure PRO at high strength settings. Prolonged use at high settings may cause muscle injury or tissue inflammation.
No serious or long-term adverse effects have been reported. Mild adverse reactions are very rarely reported, but these have included muscular pain and cramps, vaginal tenderness, irritation and bleeding, mild or short-term urge or faecal incontinence, and tingling sensation in legs. If you experience any of these, stop use. When symptoms have gone, try resuming at a lower intensity setting.
Probe Cautions
The Sure PRO vaginal probe is intended for single patient use only.
Do NOT share your Sure PRO probe with anyone else. Improper treatment or cross-infection may occur.
This probe is intended for single orifice use only (intra-vaginal or intra-anal use). Improper treatment or cross-infection may occur.
It is important that the vaginal probe is cleaned after each use. Ineffective cleaning may lead to irritation or infection.
Never insert or remove vaginal probe unless the control unit is powered OFF as insertion or removal when stimulation is active may cause discomfort or tissue irritation.
If tissue irritation occurs, discontinue treatment immediately. Ask your healthcare professional for advice before continuing further treatment to prevent injury.
Do NOT use a silicone-based lubricant on the metal plates of the probe as it may decrease the effectiveness of Sure PRO’s muscle stimulation.
The stainless steel in the probe’s metal plates contain some Nickel. This could cause a reaction if you have a Nickel allergy. Alternative gold probe specially made without Nickel is available.
Use with caution if you have a copper IUD. If discomfort occurs, discontinue treatment immediately and ask your healthcare professional for advice.
There is a small risk of stimulating the uterine wall if the IUD is not correctly positioned.
Do NOT use this device with vaginal probe, anal probe or electrode pads other than those recommended by the manufacturer.
Electrode Pads Cautions
Do NOT use on skin, which does not have normal sensation. If the skin is numb too great a strength may be used, which could result in skin inflammation.
Do NOT use on broken skin. The electrode pads could encourage infection.
Do NOT use on the neck/throat. This could cause respiratory closures and discomfort in breathing. This could also cause blood pressure to drop (vagal discomfort).
Do NOT use on over the eyes. This can affect sight or cause headaches.
Do NOT use on across the forehead.
Do NOT ignore any allergic reaction to the electrode pads: if a skin irritation develops, stop using TENS, as this type of electrodes may not be suitable for you. Alternative electrode pads specially made for sensitive skin are available.
Do NOT use this device with leads or electrode pads other than those recommended by the manufacturer. Performance may vary from specification.
Electrodes with smaller surface area may cause tissue irritation.
Additional Cautions
Do NOT immerse your device in water or place it close to excessive heat such as a fireplace or radiant heater or sources of high humidity such as a nebulizer or kettle as this may cause it to cease to operate correctly.
Keep the device away from sunlight, as long-term exposure to sunlight may affect the rubber causing it to become less elastic and crack.
Keep the device away from lint and dust, as long-term exposure to lint or dust may affect the sockets or cause the battery connector to develop a bad contact.
Do NOT attempt to open or modify the TENS unit. This may affect the safe operation of the unit and will invalidate the warranty.